GUDE-PDU-1 x 16 A- 16 x IEC C13- 4 x IEC C19- 2 sensor connectors-vertical mountSSL- IPv6- SNMPv3

GUDE - power management & monitoring
GUDE-PDU-1 x 16 A- 16 x IEC C13- 4 x IEC C19- 2 sensor connectors-vertical mountSSL- IPv6- SNMPv3

GS-87-1210-18

Key Features Event and schedule controlled switching Precise current metering of up to 9 electrical units and residual current 2 connectors for plug-and-play sensors No height unit required due to vertical installation in the rack Simple and quick mounting due to integrated mounting straps NTP function can be activated Integrated overvoltage protection type 3

Features & Benefits

  • Switching function Each power port can be switched via HTTP(S), SNMP, ModbusTCP or command line interface via Telnet, SSH and MQTT Programmable on/off sequences for remote reboots (Remote Reboot) Power ports can be switched when preset sensor thresholds are exceeded Self-healing function thanks to 20-channel watchdog: Each power port can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second Metering function Power consumption metering (kwH) with 2 energy counters: one counter counts consistently, the other counter is resettable Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr) 2 connectors for combined plug-and-play sensors (temperature, humidity and air pressure) to prevent often occurring physical hazards like overheating and increased humidity or air pressure Security Integrated overvoltage protection type 3 prevents damage to the device and connected loads Long-life High-Inrush Relays prevent welding of relay contacts during inrush current peaks Generation of status messages and alarms (e-mail, syslog, SNMP traps MQTT, SSH, Telnet) Encrypted e-mails (SSL, STARTTLS) Access protection by IP access control Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH Password protected access Beeper for audible alarm when sensor limits are exceeded/deceeded Operation Easy-to-read LED display for displaying total current, IP address and sensor values Firmware update via Ethernet during operation (no restart required) Simple and flexible configuration via web browser, Windows or Linux program Dynamic assignment of an IP address via DHCP or manual assignment of static IP address Rapid commissioning thanks to free and reliable drivers from our technology partners